DSSV

Features

•Protects telephone line equipment (telephone, modem, facsimile etc.)against surge and over voltage (UL1459, CSA-22.2 No. 225-M90).

Dimensions

Characteristics

Part Number
DC spark-over
voltage Vs
Insulation resistance
IR
Electrostatic
capacitance
1kHz-6V max.
Surge current
capacity
8/20μsec.
Surge life
test
UL recognized
UL 497A 3)
DSSV-201M-YD
200V (160〜240)
100MΩmin.
DC 100V
2pF max
400A
FCCcycle 1)
DSSV-301L-YD
300V (255〜345)
DOC 1cycle 2)
DSSV-401M-YD
400V (320〜480)
DC 250V
1): FCC10/560μsec. 100A±3times, 10/160μsec. 200A±3times
2): DOC 1cycle 10/1000μsec. 1KV-12times, 100/1000μsec. 1KV-12times respectively.
3): UL Standard UL 497A File No. E131010

Overvoltage cut off properties of DSSV type

Part number DSSV-301L-YD, DSSV-401M-YD
Applied conditions AC600V-40A-1.50sec. AC600V-7A-5sec. AC600V-2.2A-30min.
Rate of ignition n=100 0 0 0

Overvoltage testing is required in both UL60950 and CSA-C22.2 No.225-M90.
The DSSV is effective in protecting against these overvoltage conditions by opening the circuit.